170-17 Monitoring Glyphosate and AMPA Concentrations in Wells and Drains Using the Sorbicell Passive Sampler.
Poster Number 2429
See more from this Division: S11 Soils & Environmental QualitySee more from this Session: S11 General Soils & Environmental Quality: Metal/Metalloid Interactions in Soil
When installed in a well the SorbiCell will continuously sample the water giving either a flux-weighed or time-weighted average measurement of the glyphosate/AMPA concentration throughout the sampling period. It may therefore be possible to measure lower concentrations as the glyphosate/AMPA sorbed in the SorbiCell is an accumulated measurement. Also, glyphosate/AMPA associated with sudden flush events will be detected by the SorbiCells, while such events may pass between two consecutive grab samples.
To document the ability of the SorbiCell to capture glyphosate/AMPA, a series of laboratory flow experiments were carried out. Sorption and release from the flow cells is tested with two influent solutions (0.15 µg/l and 5 µg/l), one of demineralized water and the other with drain water from the Silstrup site (part of the Danish Pesticide Leaching Assessment Program, PLAP), spiked with 14C marked glyphosate. Two different volumes of effluent were then eluted through Sorbicell’s with two different capacities. The concentration of glyphosate/AMPA was continuously measured in both the influent and effluent.
The aim of the study is to test and verify if the glyphosate/AMPA sensitive SorbiCell is an efficient and reliable, and cost-effective technology for groundwater and drainwater monitoring of pesticides.
See more from this Session: S11 General Soils & Environmental Quality: Metal/Metalloid Interactions in Soil